A fog machine, fog generator, or smoke machine is a device that emits a dense vapor that appears similar to fog or smoke. This artificial fog is most commonly used in professional entertainment applications, but smaller, more affordable fog machines are becoming common for personal use. Fog machines can also be found in use in a variety of industrial, training, and some military applications. Typically, fog is created by vaporizing proprietary water and glycol-based or glycerin-based fluids or through the atomization of mineral oil. This fluid (often referred to colloquially as fog juice) vaporizes or atomizes inside the fog machine. Upon exiting the fog machine and mixing with cooler outside air, the vapor condenses, resulting in a thick, visible fog.
Types
editHeated
editHeated fog machines use either an inert gas or an electric pump to propel mineral oil, propylene glycol, or glycerin and water mixture into a heat exchanger, where the solution is vaporized. The most commonly encountered form of heated fog machine is the pump machine. Very basic models of this type of machine consist of a fluid reservoir, an electric pump to move the fog fluid, and a heat exchanger, which vaporizes the fluid. More complex models may include a variety of other features, including variable speed pumps to control the output of fog, timer modules, or components for remote operation and monitoring of the fog machines' status. Some manufacturers have produced accessories and fluids that when combined with an ordinary heated pump machine, create fog effects similar to chilled fog machines. Gas propelled fog machines use an inert gas (most commonly CO2 or nitrogen) to propel either mineral oil or a glycol based fluid into a heat exchanger, where it is vaporized into particles, creating a fog. Some models of gas propelled fog machine provide control over the output of fog by varying the volume of gas used to propel the fluid.
Chilled
editChilled fog machines are designed to create thick clouds of fog that lie close to the ground and dissipate as they rise. They are typically created by using either dry ice, compressed liquid CO2, liquid nitrogen, ice or more recently liquid air.
Dry ice (solid CO2) effects are produced by heating water to or near boiling in a suitable container (for example: a 55-gallon drum with water heater coils in it), and then dropping in one or more pieces of dry ice. Because at standard temperature and pressure carbon dioxide is a gas, the carbon dioxide sublimes and instantly produces a gas, condensing water vapor and creating a thick white fog. Liquid nitrogen (N2) can be used in a similar manner to dry ice. In either case, a fan placed at the top of the container directs the fog where it is needed.
Liquid air is an alternative to using liquid nitrogen in generating low lying fog effects. Liquid air is composed of N2 and O2 mixed in a ratio of 79% nitrogen and 21% oxygen stored as a liquid in insulated cylinders. This ratio of nitrogen to oxygen is the same as that of atmospheric air, and indeed liquid air may be fabricated by simply liquefying atmospheric air. Liquid air can be used as a direct replacement for liquid nitrogen in chilled-fog effects and is intended to be used in the same manner in the same equipment. Its key advantage over liquid nitrogen is that it presents no asphyxiation hazard, since it contains oxygen. A disadvantage is that it supports combustion, whereas liquid nitrogen inhibits combustion.
Uses
editThe versatility of fog machines make them appropriate for a wide variety of applications: Fog readily assists in creating a specific mood or feeling for a theatrical moment, and is often used in plays, such as Dracula, A Christmas Carol and Macbeth. Fog machines are also frequently used in Halloween displays such as haunted houses or forests. Because of greater availability and reductions in prices between 2003 and 2005, fog machines have become widely used for domestic Halloween presentations. Fog machines are also useful for industrial applications including visualizing the flow of air, such highlighting drag over a surface in a wind tunnel or testing for leaks or filter effectiveness in air conditioning installations. Emergency and military services also use fog machines in their training regimens. Because of the reflective and refractive qualities of the smoke created by fog machines, they are often used in nightclubs and other entertainment venues to enhance the effects of lighting and laser arrangements, although they are being superseded by haze machines (see also light beam). Several companies in Europe and Canada have developed rapid deployment fog machines for use as intrusion and hold-up security systems, intended to disorient an intruder by filling a room with fog when triggered by a panic button or other security device. These security smoke devices can produce between 300 and 1,000 cubic meters (11,000 and 35,000 cu ft) of smoke in 30 seconds and have been utilized in a wide variety of industries, including buildings requiring a high level of security, such as banks and jewelers, but also warehouses, offices, retail premises and in cash-handling chains. Concerns have been raised, that these devices may cause criminals to panic, causing them to become violent to customers or staff,[1] however security smoke now has its own European Standard EN-8 which specifically states that it must not be installed in such a way as to create a mantrap.[2]
Industrial uses
editUltra Low Volume (ULV) fogging is used by pest control industry and cleaning companies. ULV refers to the droplet size (between 20–30 micrometers (0.00079–0.00118 in)) generated by these fog machines. This fine droplet size is known[3] as the optimum size for pest control. Traditional thermal fog machine technology has difficulty reaching crawling pests such as roaches, flea, and rodents due to the droplet size being too fine (less than 10 micrometers (0.00039 in)). It is often found that small droplets are blocked by the "air-curtain" of insects and rodents.[citation needed][3] Cold Fogging, in contrast, is heavy enough to penetrate these "air-curtains" as well as light enough to be evenly distributed within a room.
Adverse health effects
editDry ice- and liquid nitrogen-based fog
editAtmospheric effects generated using water and dry ice or liquid nitrogen can present asphyxiation or breathing hazards. Both carbon dioxide and nitrogen displace ordinary air and the oxygen it contains, creating a risk of subtle anoxia (lack of oxygenation) for people working in these atmospheres. Adequate ventilation is essential to ensure that artists and technicians are surrounded by breathable air. Carbon dioxide has the added hazard of interfering with the normal breathing reflex, which is sensitive to carbon dioxide levels in the air. Nitrogen has no effect on the breathing reflex, but this creates its own hazard in that a person breathing pure nitrogen can lose consciousness from lack of oxygen without any warning signs.
Liquid air fog
editFog produced with liquid air does not present the hazards of carbon dioxide or liquid nitrogen because the liquid air has the same composition as ordinary atmospheric air (including the same level of breathable oxygen).
Fog machines which generate their effects solely using water, such as ultrasonic or pressurized technology, pose no special health risks, however "water-based" fog fluid commonly contains glycol or glycerin.
Glycerin-based fog
editGlycerin has a boiling point of 290 °C (554F degrees), considerably higher than the temperature required for fog to be created.[4] Thus, the thermostable range for glycerin is unlikely to be exceeded in normal commercial fogging operation, and so glycerin will not break down into other molecules due to heat at these temperatures.
Glycerin has been tested for safety in 62 tests by the National Institutes for Occupational Safety and Health (NIOSH). These tests include toxicity testing, eye irritation, skin irritation and several others.[5]
Glycol-based fog
editA number of studies have been published on the potential health effects presented by exposure to glycol-based theatrical fogs and artificial mists.
Two studies, a Health Hazard Evaluation completed in 1994 by the National Institute for Occupational Safety and Health,[6] and another one in 2000 by the Department of Community and Preventative Medicine at the Mount Sinai School of Medicine and ENVIRON;[7] both prepared for Actors Equity and the League of American Theaters and Producers, focused on the effects on actors and performers in Broadway musicals. The conclusion of both studies was that there was irritation of mucous membranes such as the eyes and the respiratory tract associated with extended peak exposure to theatrical fog. Exposure guidelines were outlined in the 2000 study that, it was determined, should prevent actors from suffering adverse impact to their health or vocal abilities.
Another study[8] focused on the use of theatrical fog in the commercial aviation industry for emergency training of staff in simulated fire conditions. This study also found eye and respiratory tract irritation.
In May 2005, a study published in the American Journal of Industrial Medicine,[9] conducted by the School of Environment and Health at the University of British Columbia, looked at adverse respiratory effects in crew members on a wide variety of entertainment venues ranging from live theaters, concerts, television and film productions to a video arcade. This study determined that cumulative exposure to mineral oil and glycol-based fogs were associated with acute and chronic adverse effects on respiratory health. This study found that short-term exposure to glycol fog was associated with coughing, dry throat, headaches, dizziness, drowsiness, and tiredness. This study also found long-term exposure to smoke and fog was associated with both short-term and long-term respiratory problems such as chest tightness and wheezing. Personnel working closest to the fog machines had reduced lung function results.
The Professional Lighting and Sound Association has compiled a standard for theatrical fogs or artificial mists compositions for use in entertainment venues that "are not likely to be harmful to otherwise healthy performers, technicians, or audience members of normal working age, which is 18 to 64 years of age, inclusive."[10] This standard was based primarily (though not exclusively) upon the findings of a report commissioned for them by the Cohen Group[11] and applies to only those fog fluid compositions that consist of a mixture of water and glycol (so-called "water based" fog fluid).
Short-term exposure to glycol fog can be associated with headaches, dizziness, drowsiness and tiredness. Long-term exposure to smoke and fog can be related to upper airway and voice symptoms. Extended (multi-year) exposure to smoke and fog has been associated with both short-term and long-term respiratory health problems. Efforts should be made to reduce exposure to theatrical smoke to as low a level as possible. The use of digital effects in post production on film and television sets can be considered a safer practise than using theatrical smoke and fog during filming,[12] although this is not always practical.
Haze machines
editHaze machines, also called haze generators or hazers, produce atmospheric effects (haze) which tend to be less dense than that of fog machines, allowing them to be used in creating more subtle looks. Depending on a venue's or location's ventilation, this haze can stay in the air for hours. Because of the small particle size of the output from hazers, under 5 micrometres, a hazer typically takes longer to fill the same volume of space with a visible effect relative to a fog machine.[13]
See also
editReferences
edit- ^ "What is a fogging device?". BBC News. 8 June 2009. Retrieved 2009-07-02.
- ^ Folders/prose-07-09/News-Bsiasmoke.htm BIA Welcomes new European Standard[dead link ]
- ^ a b "Fog Machines: The Optimal Pest Control Droplet Size". Mackay Pest Control. Retrieved 2016-09-22.
- ^ National Institute for Occupational Safety and Health [NIOSH Pocket Guide to Chemical Hazards - https://www.cdc.gov/niosh/npg/npgd0302.html Glycerin (mist) - Centers for Disease Control and Prevention]
- ^ Glycerine - NIOSH Toxicity Data
- ^ Burr GA, Van Gilder TJ, Trout DB, Wilcox TG, Driscoll R. NOSH Health Hazard Evaluation ETA 90-0355-2499. Actor's Equity Association.
- ^ Moline JM, Golden AL, Highland JH, Walmart KR, Kao AS. Health Effects Evaluation of Theatrical Smoke, Haze and Pyrotechnics. Prepared for Actor's Equity Pension and Health Trust Funds. June 6, 2000.
- ^ Weislander G, Norback D, Lindgren T. Experimental exposure to propylene glycol mist in aviation emergency training: acute ocular and respiratory effects. Occupational and Environmental Medicine. 2001 Oct;58(10):649-55.
- ^ Varughese S, Teschke K, Bauer M, Chow Y, van Netten C, Kennedy SM. Effects of theatrical smokes and fogs on respiratory health in the entertainment industry. American Journal of Industrial Medicine. 2005 May;47(5):411-8.
- ^ ANSI HE'.5 - 2003, Entertainment Technology - [Theatrical Fog Made With Aqueous Solutions Of Di- And Triadic Alcohols F&S/1997-3017r7.5 Theatrical Fog Made With Aqueous Solutions Of Di- And Trihydric Alcohols F&S/1997-3017r7.5]
- ^ Gregory E. Raymond, Recommended Exposure Liquid Fogging Agents Archived 2013-01-19 at archive.today
- ^ Teschke K, Chow Y, van Netten C, Varughese S, Kennedy SM, Bauer M. Exposures to atmospheric effects in the entertainment industry. Journal of Occupational and Environmental Hygiene. 2005 May;2(5):277-84.
- ^ "Wie funktioniert eine Nebelmaschine?". www.nebelmaschine-check.de. Retrieved 13 June 2016.
External links
edit- [1] NIOSH 1994 report on theatrical smoke in Broadway Productions
- [2] Article examining the pros and cons of Fog machines as security devices.
- [3] Technical report from University of British Columbia School of Environment and Health on special effects smoke and fog]
- [4] Master's thesis on Respiratory Health Impacts in the Entertainment Industry from Exposure to Theatrical Smokes and Fogs.