Passive house

(Redirected from Passivhaus)

Passive house (German: Passivhaus) is a voluntary standard for energy efficiency in a building that reduces the building's carbon footprint.[1] Conforming to these standards results in ultra-low energy buildings that require less energy for space heating or cooling.[2][3][4][5][6] A similar standard, MINERGIE-P, is used in Switzerland.[7] Standards are available for residential properties, and several office buildings, schools, kindergartens and a supermarket have also been constructed to the standard. Energy efficiency is not an attachment or supplement to architectural design, but a design process that integrates with architectural design.[8] Although it is generally applied to new buildings, it has also been used for renovations.

A building based on the passive house concept in Darmstadt, Germany

In 2008, estimates of the number of passive house buildings around the world ranged from 15,000 to 20,000 structures.[9][10] In 2016, there were approximately 60,000 such certified structures of all types worldwide.[11] The vast majority of passive house structures have been built in German-speaking countries and Scandinavia.[9]

History

edit
Bo Adamson, co-originator of the passive house concept
Wolfgang Feist, co-originator of the passive house concept, and founder of the Passivhaus-Institut in Germany

The term passive house has had at least two meanings in the literature. Its earlier meaning, used since the 1970s, was for a low-energy building designed to exploit passive solar technologies and establish a comfortable indoor temperature with a low-energy requirement for heating or cooling. More recently the term has been used to indicate a building that is certified to meet the criteria for the passive house standard, including heating, cooling and primary energy demands in addition to airtightness, thermal comfort requirements and non-heating related energy demands.[12]

The passive house standard originated from a conversation in May 1988 between Bo Adamson of Lund University, in Sweden, and Wolfgang Feist of the Institut für Wohnen und Umwelt (Institute for Housing and Environment), in Darmstadt, Germany.[13] Their concept was developed through a number of research projects with financial assistance from the German state of Hesse.[14]

Many of the early passive house builds were based on research and the experience of North American builders during the 1970s, who—in response to the OPEC oil embargo—sought to build homes that used little to no energy.[15] These designs often utilised expansive solar-gain windows, which used the sun as a heat source. However, superinsulation became a key feature of such efforts, as seen in the Saskatchewan Conservation House in Regina, Saskatchewan, (1977) and the Leger House in Pepperell, Massachusetts (1977).[16] The Saskatchewan Conservation House was a project of the Saskatchewan Research Council (SRC) with Harold Orr as its lead engineer.[17] The team independently developed a heat recovery air exchanger, hot water recovery, and a blower-door apparatus to measure building air-tightness.[18] Notably, the house was designed for the extreme −40°C to +40°C climate of the Canadian Prairies. The SRC and Leger houses were predated by the Lyngby, Denmark house (1975), developed by the Technical University of Denmark, and several homes were built between 1977 and 1979 based on the Lo-Cal house design (1976) developed by the University of Illinois at Urbana–Champaign.[19]

The term passive can be partly attributed to William Shurcliff, an American physicist who contributed to the WWII Manhattan Project, and in the 1970s became an advocate for energy-efficient home design:

What name should be given to this new system? Superinsulated passive? Super-save passive? Mini-need passive? Micro-load passive? I lean toward ‘micro-load passive.’ Whatever it is called, it has (I predict) a big future.

— William Shurcliff, [20]

An early book explaining the concepts of passive house construction was The Passive Solar Energy Book by Edward Mazria in 1979.[21]

First examples

edit

The eventual construction of four row houses (terraced houses or town homes) were designed for four private clients by the architectural firm Bott, Ridder and Westermeyer. The first passive house residences were built in Darmstadt in 1990, and occupied the following year.

Further implementation and councils

edit
 
The Schiestlhaus [de], in the Hochschwab Alps of Austria, was completed in 2005 and was the first passive house constructed in a high alpine setting.

In September 1996, the Passivhaus-Institut was founded in Darmstadt to promote and control passive house standards. By 2010 more than 25,000 passive house structures were estimated to have been built.[1][9][22] Most are located in Germany and Austria, others in various countries worldwide.

In 1996, after the concept had been validated at the Institute in Darmstadt, with space heating at 90% less than that required for a standard new building at the time, the economical passive houses working group was created. This group developed the planning package and initiated the production of the innovative components that had been used, notably the windows and the high-efficiency ventilation systems. Meanwhile, further passive houses were built in Stuttgart (1993), Naumburg, Hesse, Wiesbaden, and Cologne (1997).[23]

Products that had been developed according to the passive house standard were further commercialized during and following the European Union sponsored CEPHEUS project, which proved the concept in five European countries in the winter of 2000–2001. The first certified house was built in 2006 near Bemidji, Minnesota, in Camp Waldsee of the German Concordia Language Villages.[24] The first US passive retrofit project, the remodeled craftsman O'Neill house in Sonoma, California,[25] was certified in July 2010.

In the United States, passive house design was first implemented by Katrin Klingenberg in 2003 when she built a passive home prototype named "The Smith House" in Urbana, Illinois.[26] Later, she and builder Mike Kernagis co-founded the Ecological Construction Laboratory in 2004 to further explore the feasibility of the affordable passive design.[27] It eventually led to the inception of the Passive House Institute United States (PHIUS) in 2007.[28] Afterwards, the PHIUS has released their PHIUS + 2015 Building Standard and has certified over 1,200 projects and 1.1 million square feet (100,000 m2) across the United States.[28] In 2019, Park Avenue Green, a low-income housing building in New York was built with passive house standards. The building later became the largest certified passive house in North America.[29]

Ireland's first passive house[30] was built in 2005 by Tomas O'Leary, a "passive house" designer and teacher. The house was called 'Out of the Blue'. Upon completion, Tomas moved into the building.[31]

The world's first standardised passive prefabricated house was built in Ireland in 2005 by Scandinavian Homes[32][33] a Swedish company, that has since built more passive houses in England and Poland.[34]

The first certified passive house in Antwerp, Belgium, was built in 2010.[35] In 2011, Heidelberg, Germany, initiated the Bahnstadt project, which was seen as the world's largest passive house building area.[36] A company in Qatar planned the country's first Passive House in 2013,[37] the first in the region.

The world's tallest passive house was built in the Bolueta neighborhood in Bilbao, Spain. At 289 feet (88 m), it is currently the world's tallest building certified under the standard in 2018. The $14.5 million, 171-unit development (including a nine-story companion to the high-rise) consists entirely of social housing.

Gaobeidian, China, hosted the 23rd International Passive House Conference in 2019, and later built the Gaobeidian Railway City apartment complex which is reported to be "the world's largest passive house project".[38] China have taken a leadership role in passive house construction, with 73 different companies "making windows to the 'passive house' standards."[38]

The United Kingdom’s first passive house health centre in Foleshill was opened in November 2021.[39]

Standards

edit
 
The dark colours on this thermogram of a Passive house, at right, shows how little heat is escaping compared to a traditional building to the left.

While some techniques and technologies were specifically developed for the passive house standard, others, such as superinsulation, already existed, and the concept of passive solar building design dates back to antiquity. There were other previous buildings with low-energy building standards, notably the German Niedrigenergiehaus (low-energy house) standard, in addition to buildings constructed to the demanding energy codes of Sweden and Denmark.

International passive house standard

edit

The passive house standard requires that the building fulfills the following requirements:[40][41][42]

  • Use up to 15 kWh/m2 (4,755 BTU/sq ft; 5.017 MJ/sq ft) of floor area per year for heating and cooling as calculated by the Passivhaus Planning Package, or a peak heat load of 10 W/m2 (1.2 hp/1000 sq ft) of floor area based on local climate data.
  • Use up to 60 kWh/m2 (19,020 BTU/sq ft; 20.07 MJ/sq ft) of floor area per year primary energy (for heating, hot water and electricity).
  • Leak air up to 0.6 times the house volume per hour (n50 ≤ 0.6 / hour) at 50 Pa (0.0073 psi) as tested by a blower door; or up to 0.05 cubic feet per minute (1.4 L/min) per square foot of the surface area of the enclosure.

Recommendations

edit

The specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10 W/m2 (3.17 btu/(h⋅ft2)).

These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below.

National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally.[43]

Passive house standards in the US - Passive House Standard and PHIUS+

edit

In the US there are two versions of passive house being promoted by two separate entities: the Passive House Institute (PHI) and the Passive House Institute US (PHIUS).[44]

PHIUS was originally an affiliate and approved trainer and certifier for the Passive House Institute. In 2011, PHI cancelled its contract with PHIUS for misconduct.[45] PHIUS disputed the claims by PHI and continued working to launch an independent building performance program.

In 2015 PHIUS launched its own PHIUS+ standard, which primarily focuses on reducing negative effects of building operations for any type of building. This standard also uses climate data sets to determine specific building performance criteria for different regions. Such information is determined using metrics that represent a space where significant carbon and energy reduction overlap with cost-effectiveness.[46] Overall, the PHIUS database includes more than 1,000 climate data sets for North America.[46]

The standard is based on five principles: airtightness, ventilation, waterproofing, heating and cooling, and electrical loads.[47] Within these principles, projects must pass building specified blower door, ventilation airflow, overall airflow, and electrical load tests; buildings must also achieve other measures such as low-emission materials, renewable energy systems, moisture control, outdoor ventilation, energy efficient ventilation and space conditioning equipment.[47] All buildings must also pass a quality assurance and quality control test – this is implemented to ensure that the building continues to adhere to the regional criteria set forth by the PHIUS’ climate data.[47] These tests and analyses of operative conditions are performed by PHIUS raters or verifiers. These are accredited professionals from the PHIUS that are able to perform on-site testing and inspections to ensure that the newly constructed building is adhering to the construction plans, created energy models, and desired operating conditions.[48]

The two standards (passive house and PHIUS+) are distinct and target different performance metrics and use different energy modeling software and protocols.

Construction costs

edit

In passive house buildings, the cost savings from replacing the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed passive house building products, in Germany it is currently possible to construct buildings for the same cost as those built to normal German building standards, as was done with the passive house apartments in Vauban, Freiburg.[49] On average, passive houses are reported to be more expensive upfront than conventional buildings: 5% to 8% in Germany,[50][51] 8% to 10% in UK[52] and 5% to 10% in USA.[53][54][55][56]

Evaluations have indicated that while it is technically possible, the costs of meeting the passive house standard increase significantly when building in Northern Europe above 60° latitude.[57][58] European cities at approximately 60° include Helsinki, Finland, and Bergen, Norway. London is at 51°; Moscow is at 55°.

Design and construction

edit
 
The Passivhaus uses a combination of low-energy building techniques and technologies.

Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design may be assisted by use of the Passivhaus Planning Package (PHPP),[59] which uses specifically-designed computer simulations.

Below are the techniques used to achieve the standard.[2]

Passive solar design and landscape

edit

Passive solar building design and energy-efficient landscaping support passive house energy conservation and can integrate them into a neighborhood and environment. Following passive solar building techniques, where possible buildings are compact in shape to reduce their surface area; principal windows are oriented towards the equator to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the overall house energy requirements. In climates and regions needing to reduce excessive summer passive solar heat gain, whether from direct or reflected sources, brise soleil, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.

Exterior wall color, when the surface allows a choice for reflection or absorption insolation qualities, depends on the predominant year-round ambient outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in climates not at the temperature extremes.

Superinsulation

edit

Passive house buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings.[60] A wide range of thermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m2·K) range). Special attention is given to eliminating thermal bridges.

Advanced window technology

edit
 
Typical passive-house windows

To meet the requirements of the passive house standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.45 W/(m2·K) for the entire window including the frame). The windows normally combine triple or quadruple-pane insulated glazing (with an appropriate solar heat-gain coefficient,[2][60] low-emissivity coatings, sealed argon or krypton gas filled inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermal break window frames.

Air tightness

edit

Building envelopes under the passive house standard are required to be extremely airtight compared to conventional construction. They are required to meet 0.60 ACH50 (air changes per hour at 50 pascals) based on the building's volume. In order to achieve these metrics, best practice is to test the building air barrier enclosure with a blower door at mid-construction if possible.[2][61]

A passive house is designed so that most of the air exchange with exterior is done by controlled ventilation through a heat-exchanger in order to minimize heat loss (or gain, depending on climate), so uncontrolled air leaks are best avoided.[2] Another reason is the passive house standard makes extensive use of insulation which usually requires a careful management of moisture and dew points.[62] This is achieved through air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations.[60]

Ventilation

edit

Use of passive natural ventilation is an integral component of passive house design where ambient temperature is conducive—either by singular or cross ventilation, by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.

When ambient climate is not conducive, mechanical heat recovery ventilation systems with a heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM) are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed against leakage.

Some passive house builders promote the use of earth warming tubes. The tubes are typically around 200 millimetres (7.9 in) in diameter, 40 metres (130 ft) long at a depth of about 1.5 metres (4.9 ft). They are buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather, the warmed air also prevents ice formation in the heat recovery system's heat exchanger. Concerns about this technique have arisen in some climates due to problems with condensation and mold.[63]

Space heating

edit
 
In addition to the heat exchanger (centre), a micro-heat pump extracts heat from the exhaust air (left) and hot water heats the ventilation air (right). The ability to control building temperature using only the normal volume of ventilation air is fundamental.

In addition to using passive solar gain, passive house buildings make extensive use of their intrinsic heat from internal sources—such as waste heat from lighting, major appliances and other electrical devices (but not dedicated heaters)—as well as body heat from the people and other animals inside the building. This is due to the fact that people, on average, emit heat equivalent to 100 watts each of radiated thermal energy.

Together with the comprehensive energy conservation measures taken, this means that a conventional central heating system is not necessary, although they are sometimes installed due to client's skepticism.[64]

Instead, passive houses sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system.

Beyond the recovery of heat by the heat recovery ventilation unit, a well-designed passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10 W/m2.[65][dead link]

The passive house standards in Europe set a space heating and cooling energy demand of 15 kWh/m2 (4,750 BTU/sq ft) per year, and 10 W/m2 (3.2 Btu/h/sq ft) peak demand. In addition, the total energy to be used in the building operations including heating, cooling, lighting, equipment, hot water, plug loads, etc. is limited to 120 kWh/m2 (38,000 BTU/sq ft) of treated floor area per year.[66][dead link]

Traits of passive houses

edit
  • Some[who?] have voiced concerns that the passive house standard is not a general approach as the occupant has to behave in a prescribed way; for example, not opening windows too often. A 2013 study concluded that in general passive houses are less sensitive to such behaviour than anticipated.[67]

International comparisons

edit
  • In the United States, a house built to passive house standard results in a building that requires space heating energy of 1 British thermal unit per square foot (11 kJ/m2) per heating degree day, compared with about 5 to 15 BTU/sq ft (57 to 170 kJ/m2) per heating degree day for a similar building built to meet the 2003 Model Energy Efficiency Code. This is between 75 and 95% less energy for space heating and cooling than current new buildings that meet today's US energy efficiency codes. The passive house in the German-language camp of Waldsee, Minnesota, was designed by architect Stephan Tanner of INTEP, LLC, a Minneapolis- and Munich-based consulting company for high performance and sustainable construction. Waldsee BioHaus is modeled on Germany's passive house standard and, when compared to houses of the U.S. LEED standard, shows improvement to the quality of life inside the building while using 85% less energy than a house built to the latter standard.[68] VOLKsHouse 1.0 was the first certified "passive house" offered and sold in Santa Fe New Mexico.[69]
  • In the United Kingdom, an average new house built with the passive house standard used 77% less energy for space heating compared to the house built under circa-2006 Building Regulations.[70]
  • In Ireland, a typical house built to passive house standards instead of to the 2002 Building Regulations consumed 85% less energy for space heating and cut space-heating related carbon emissions by 94%.[71]

Tropical climate needs

edit

A certified passive house was built in the hot and humid climate of Lafayette, Louisiana, USA. It uses energy recovery ventilation and an efficient one-ton air-conditioner to provide cooling and dehumidification.[72][73]

See also

edit

References

edit
  1. ^ a b Zeller, Tom Jr. (September 26, 2010). "Beyond Fossil Fuels: Can We Build in a Brighter Shade of Green?". The New York Times. p. BU1.
  2. ^ a b c d e f Gröndahl, Mika; Gates, Guilbert (September 25, 2010). "The Secrets of a Passive House". The New York Times. Retrieved September 27, 2010.
  3. ^ "Definition of Passive House". PassivHaustagung.de. Archived from the original on October 5, 2012.
  4. ^ Thomson, Emily. "The homes on the rise in Norfolk, but what is a Passivhaus?". Eastern Daily Press. Retrieved 2018-08-07.
  5. ^ "Passivhäuser halten Sommerhitze gut stand". EnBauSa News: Energetisch Bauen und Sanieren (in German). Retrieved 2018-08-07.
  6. ^ "Chicago's Most Energy Efficient Home Resides In Hyde Park". CBS Local Chicago. 2018-02-05. Retrieved 2018-08-07.
  7. ^ "Minergie-Standard". Minergie.ch (in French). Archived from the original on November 18, 2007.
  8. ^ Ji, Yan; Plainiotis, Stellios (2006). Design for Sustainability. Beijing: China Architecture and Building Press. ISBN 978-7-112-08390-9.
  9. ^ a b c Rosenthal, Elisabeth (December 26, 2008). "Houses With No Furnace but Plenty of Heat". The New York Times. Retrieved December 27, 2008.
  10. ^ "Timber Frame takes the Passivhaus tour". Building Talk.com. January 23, 2009. Archived from the original on February 15, 2012. Retrieved June 5, 2009.
  11. ^ "Passipedia: Examples". Passipedia.org. December 6, 2018. Archived from the original on January 16, 2022. Retrieved October 14, 2022.
  12. ^ Ürge-Vorsatz, Diana; Khosla, Radhika; Bernhardt, Rob; Chan, Yi Chieh; Vérez, David; Hu, Shan; Cabeza, Luisa F. (2020-10-17). "Advances Toward a Net-Zero Global Building Sector". Annual Review of Environment and Resources. 45 (1): 227–269. doi:10.1146/annurev-environ-012420-045843. ISSN 1543-5938.
  13. ^ "Home". Institute for Housing and the Environment. Archived from the original on December 12, 2017. Retrieved December 11, 2017.
  14. ^ Feist, Wolfgang (September 2006). "15th Anniversary of the Darmstadt - Kranichstein Passive House". PassivHaustagung.de. Archived from the original on July 14, 2014. Retrieved December 11, 2017.
  15. ^ "Forgotten Pioneers of Energy Efficiency". GreenBuildingAdvisor.com. 2009-04-17. Retrieved October 25, 2017.
  16. ^ "How Saskatchewan Pioneered Energy-Efficient Housing and Influenced Building Standards". Saskatchewan Research Council. March 27, 2018.
  17. ^ "The principal designer of the house that inspired the global Passivhaus movement reflects on the project that started it all". ECOHOME. October 27, 2013. Retrieved May 19, 2021.
  18. ^ "History of Super-insulated Housing in North America (presentation by Martin Holladay)" (PDF). British Columbia Building Envelope Council. September 22, 2010. Retrieved December 27, 2020.
  19. ^ "The common origins of Superinsulation, Passivhaus, and Net Zero homes". The Sustainable Home. October 14, 2012. Retrieved December 27, 2020.
  20. ^ "The Evolution of the Passive House in North America". Energy Vanguard. July 1, 2016.
  21. ^ Mazria, Edward (1979). The Passive Solar Energy Book. Emmaus, PA: Rodale Press. pp. 676 pp. ISBN 0-87857-238-4.
  22. ^ "11th International Conference on Passive Houses, 2007". PassivHaustagung.de. Archived from the original on December 31, 2008. Retrieved December 11, 2017.
  23. ^ Cox, Peter (2005). "Passivhaus" (PDF). Building for a Future. Vol. 15, no. 3. pp. 16–22. Archived from the original (PDF) on September 26, 2006. Retrieved December 11, 2017.
  24. ^ "Willkommen to Das BioHaus!". Waldsee BioHaus Environmental Living Center. Retrieved December 11, 2017.
  25. ^ "The O'Neil Retrofit Remodel". Passivworks.com. Retrieved December 11, 2017.
  26. ^ "The Smith House 2002–2003". E-colab.org. Retrieved December 11, 2017.
  27. ^ "PHIUS Milestones". Passive House Institute United States. Retrieved November 1, 2018.
  28. ^ a b "Mission & History". Passive House Institute United States. Retrieved November 1, 2018.
  29. ^ Alter, Lloyd (2019-12-12). "Park Avenue Green is the largest Passive House building in North America". TreeHugger. Retrieved 2019-12-17.
  30. ^ "Wicklow Passive House – Out of the Blue". Passive House Association of Ireland. February 3, 2013. Retrieved December 11, 2017.
  31. ^ "2002 – Out Of The Blue". MosArt.ie. Archived from the original on September 26, 2013.
  32. ^ "Passive Resistance". Construct Ireland.ie. Archived from the original on December 20, 2011. Retrieved December 11, 2017.
  33. ^ "Home". Scandinavian Homes Ltd. Retrieved December 11, 2017.
  34. ^ "How to build a house in days". Diss Express. March 5, 2009. Archived from the original on May 15, 2009. Retrieved December 11, 2017.
  35. ^ "Passive House In Beerse Near Antwerpen Belgium". r-m-p-architects.com. Retrieved December 11, 2017.
  36. ^ "Climate Seeks Protection in Heidelberg". Retrieved December 16, 2011.
  37. ^ Mandapam, Bince. "Qatar to unveil its first Passive House in 2013". Online Qatar.com. Retrieved December 11, 2017.
  38. ^ a b Alter, Lloyd (October 23, 2019). "Chinese city has the largest Passive House project in the world". TreeHugger. Retrieved 2019-10-25.
  39. ^ "Revolution in healthcare: The first NHS Passivhaus building". Building Better Healthcare. 22 November 2021. Retrieved 28 December 2021.
  40. ^ "Passive House requirements". Passivhaus Institut. Retrieved December 11, 2017.
  41. ^ "Concepts and market acceptance of a cold climate Passive House" (PDF). passivhusnorden.no. Retrieved December 11, 2017.
  42. ^ "Passivhaus Institut". passiv.de. Retrieved 2024-04-03.
  43. ^ "Promotion of European Passive Houses". EuropeanPassiveHouses.org. Archived from the original on June 28, 2012.
  44. ^ North American Passive House Network (February 2017). "Why Are There Two 'Passive Houses?". North American Passive House Network.
  45. ^ Passive House Institute (17 August 2011). "Passive House: a public good" (PDF). International Passive House Association.
  46. ^ a b "PHIUS + 2015: Passive Building Standard – North America". phius.org. Retrieved November 1, 2018.
  47. ^ a b c "PHIUS + 2015: Passive Building Standard North America Guidebook" (PDF). phius.org. Retrieved November 1, 2018.
  48. ^ "QA/QC Training Programs". phius.org. Retrieved November 1, 2018.
  49. ^ Delleske, Andreas. "What is a Passive house?". Passivhaus-vauban.de. Retrieved December 11, 2017.
  50. ^ "The Passive House – sustainable, affordable, comfortable, versatile". International Passive House Association. Retrieved December 11, 2017.
  51. ^ Hill, Steven (2010). Europe's Promise: Why the European Way Is the Best Hope in an Insecure Age. University of California Press. p. 172. ISBN 978-0-52024-857-1.
  52. ^ Siegle, Lucy (December 8, 2013). "How can I live in a passive house?". The Guardian. Retrieved December 11, 2017.
  53. ^ Loviglio, Joann (June 12, 2013). "Highly efficient 'passive homes' gain ground in US". Yahoo! News. Associated Press. Retrieved December 11, 2017.
  54. ^ Adams, Duncan (February 9, 2014). "Energized about Passive House construction". The Roanoke Times. Retrieved December 11, 2017.
  55. ^ "The buzz in energy efficiency: 'Passive house' debuts in Austin". KXAN. February 19, 2014. Retrieved December 11, 2017.
  56. ^ "Cellar Ridge's 50/10 Homes Boast 50% Greater Efficiency for 10% More Money than Similar Homes". inhabitat.com. Retrieved December 11, 2017.
  57. ^ "Passive Houses in High Latitudes" (PDF). UCD Energy Research Group, University College Dublin. Archived from the original (PDF) on March 2, 2013. Retrieved December 11, 2017.
  58. ^ "Passive Houses in cold Norwegian climate" (PDF). UCD Energy Research Group, University College Dublin. Archived from the original (PDF) on March 2, 2013. Retrieved December 11, 2017.
  59. ^ "Passivhaus Planning Package". passivehouse.com. Archived from the original on December 10, 2017. Retrieved January 21, 2018.{{cite web}}: CS1 maint: bot: original URL status unknown (link)
  60. ^ a b c Swanson, Herb (September 26, 2010). "Energy Efficiency, a Step Further". The New York Times. Retrieved September 29, 2010.
  61. ^ http://www.ecoachievers.com/notable-projects/pleasantly-tight-times-mf-passive-house/ [dead link]
  62. ^ "Insulation fact sheet". Department of Energy, Oak Ridge National Laboratory. January 15, 2008. Retrieved December 18, 2013.
  63. ^ Holladay, Martin (June 1, 2012). "Belgian Passivhaus is Rendered Uninhabitable by Bad Indoor Air". Green Building Advisor. Retrieved June 14, 2012.
  64. ^ Zeller, 2010. p.BU1. Example: in the case of the Landau home described in the NYT's article, several insurance companies refused to insure their home when they were told there was no home furnace in the structure, fearing that they would be held financially liable for frozen water pipe damage.
  65. ^ "Passive House Estate in Hannover-Kronsberg" (PDF). Passivhaustagung.de. p. 72. Retrieved December 11, 2017.
  66. ^ "What is Passive House?". passivehouseacademy.com. Retrieved December 11, 2017.
  67. ^ Blight, T. S.; Coley, D. A. (2013). "Sensitivity analysis of the effect of occupant behaviour on the energy consumption of passive house dwellings". Energy and Buildings. 66 (66): 183–192. Bibcode:2013EneBu..66..183B. doi:10.1016/j.enbuild.2013.06.030.
  68. ^ "Design & Architecture". Waldsee BioHaus Environmental Living Center. Retrieved December 11, 2017.
  69. ^ Weber, Cheryl (July 19, 2012). "EHDA Grand Award: VOLKsHouse". EcoBuilding Pulse.
  70. ^ "Energy Saving Potential of Passive Houses in the UK" (PDF). UCD Energy Research Group, University College Dublin. Retrieved December 11, 2017.
  71. ^ "Passive Houses in Ireland" (PDF). UCD Energy Research Group, University College Dublin. Archived from the original (PDF) on June 3, 2016. Retrieved December 11, 2017.
  72. ^ Defendorf, Richard (July 7, 2010). "Following Up on a Passive House in the Deep South". GreenBuildingAdvisor.com. Retrieved December 11, 2017.
  73. ^ Clearfield, Lynne (2011). "Passive House, Aggressive Conservation". Solar Today. 25 (1): 22–25.

Further reading

edit
edit